Test Price
2,000 AED✅ Home Collection Available
High-Resolution HLA DNA Typing for Kidney & Liver Transplant (PCR, Reverse SSOP – Luminex) in Dubai
Executive Summary & Core Metrics
Accuracy Guarantee: 99.9% Diagnostic Sensitivity via ISO 9001:2015 Accredited Processing (Cert: INT/EGQ/2509DA/3139).
Premium Logistics: VIP Mobile Phlebotomy & Temperature-Controlled Cold-Chain Home Collection (Available daily from 8 AM to 11 PM).
Clinical Guidance: Telephonic Post-Test Clinical Guidance in result interpretation by DHA-licensed genetics experts.
Insurance: Direct Billing Verification via WhatsApp at +971 54 548 8731.
Test Overview & Methodology
HLA DNA Typing by Reverse SSOP – Luminex is the internationally recognized gold-standard molecular assay for pre-transplant histocompatibility. This test provides high-resolution (4-digit allele) identification of Human Leukocyte Antigen loci from a standard peripheral whole blood specimen, enabling precise donor-recipient matching essential for kidney and liver graft acceptance.
The advanced Luminex platform utilizes fluorescently labeled microspheres to detect allele-specific oligonucleotide probes, delivering superior resolution and reproducibility compared to conventional PCR-SSP methods. This molecular roadmap is critical for minimizing antibody-mediated rejection and personalizing immunosuppressive protocols.
| Feature | Our Test (HLA Typing UAE) | Closest Alternative (PCR-SSP) |
|---|---|---|
| Precision / Resolution | High-resolution (4-digit allele) via Luminex SSOP | Low / medium resolution; limited allele coverage |
| Methodology | Reverse Sequence-Specific Oligonucleotide Probe – Luminex platform (ISO 9001:2015) | PCR-Sequence Specific Primers (SSP) – gel-based detection |
| Turnaround Time | 10 – 12 days | 14 – 21 days |
| Pre-Test Mandates | Prescription + donor/recipient photos + Form 33 consent | Prescription only; no formal transplant consent required |
Physician Insight & Safety Protocols
"As a Consultant Medical Geneticist specializing in histocompatibility and immunogenetics, I emphasize that high-resolution HLA typing provides the definitive molecular blueprint for solid organ transplant success. This assay identifies critical allele-level mismatches that directly influence graft survival and long-term patient outcomes. Clinical decisions, including immunosuppressive therapy adjustments, must always be made by the multidisciplinary transplant team in conjunction with this data."
— Lina Osama Zaki Quteineh, Consultant Medical Genetics, DHA Registration ID: 9294403
Critical Medication Advisory
Do not discontinue or alter prescribed immunosuppressive regimens without explicit instruction from your transplant physician. The results of this test are intended to guide clinical management, not to replace direct specialist oversight.
Exclusion Criteria & Emergency Red Flags
- Recent blood transfusion (within 2 weeks) may interfere with DNA typing; reschedule after consulting your physician.
- Severe leukopenia (WBC < 1.0 × 109/L) – alternative sample or method may be required.
- ER Red Flags: Fever >38°C, acute pain over graft site, sudden decrease in urine output (kidney) or jaundice/liver tenderness (liver) – seek immediate medical attention.
Patient FAQ & Clinical Guidance
1. How does high-resolution HLA typing improve my kidney or liver transplant outcome?
High-resolution HLA DNA typing identifies precise allele-level mismatches between donor and recipient, directly reducing the risk of antibody-mediated rejection and prolonging graft survival. This molecular detail allows your transplant team to tailor immunosuppressive therapy with greater precision.
2. Why must I provide a doctor’s prescription, photos, and Form 33 consent before the blood draw?
These documents are legally mandated under UAE organ transplantation regulations to verify consent, identity, and medical necessity, ensuring a safe and ethical transplant process in full compliance with Federal Decree-Law No. 4 of 2016 on Medical Liability.
3. I am a potential living donor; will this test also protect my own health?
Definitive high-resolution typing ensures you are a compatible match, greatly lowering the recipient’s immunological risk while confirming that donation is medically appropriate for you. The test involves a standard peripheral blood draw with no added risk to the donor.
UAE Regulatory & Data Privacy Adherence
This diagnostic service operates in full compliance with Federal Decree-Law No. 45 of 2021 on Personal Data Protection (PDPL) and Federal Law No. 2 of 2019 Concerning the Use of Information and Communication Technology in Health Fields. Clinical safety and patient consent protocols adhere strictly to Federal Decree-Law No. 4 of 2016 on Medical Liability. All testing is performed under the regulatory oversight of the Dubai Health Authority (DHA).
Clinical & Logistical Metadata
| Test Name | HLA DNA Typing for Kidney / Liver Transplant (PCR, Reverse SSOP – Luminex) |
| Price (AED) | 2,000 AED |
| Turnaround Time | 10 – 12 Days |
| Sample Type / Matrix | Peripheral Whole Blood |
| Methodology Used | Reverse Sequence-Specific Oligonucleotide Probe (SSOP) – Luminex Platform |
| ICD-10-CM Code | Z94.0, Z94.4 |
| LOINC Code | 88235-6 |
| DHA Facility License & Address | Premises 105, Floor 1, Building 33, Dubai Healthcare City, Dubai, UAE | License No: 1143 | DNA Labs UAE |
دعم ثنائي اللغة متاح
التحقق من التغطية التأمينية
Check Insurance Coverage Instantly
Stop the guesswork. Send a photo of your Insurance Card and Doctor's Prescription to our DHA-Certified Verification Team on WhatsApp.
توقف عن التخمين. أرسل صورة من بطاقة التأمين ووصفة الطبيب إلى فريق التحقق المعتمد من هيئة الصحة بدبي عبر الواتساب. احصل على تحديث الحالة في دقائق.
Available in Arabic, English, Hindi & Urdu
ISMS 27001:2022
ISO Accredited
HIPAA
All reports reviewed by DHA-Certified physicians