Test Price
1,000 AED✅ Home Collection Available
Government-Approved Transplant Form 5 DNA Test | HLA Typing | 1000 AED
Executive Summary & Core Metrics
Accuracy Guarantee: 99.9% Diagnostic Sensitivity via ISO Accredited Next-Generation Sequencing (NGS) for high-resolution HLA typing.
Premium Logistics: VIP Mobile Phlebotomy & Temperature-Controlled Cold-Chain Home Collection available daily from 8 AM to 11 PM.
Clinical Guidance: Telephonic post-test consultation for result interpretation and pre-transplant planning support.
Insurance: Direct billing verification via WhatsApp at +971 54 548 8731.
Legal Validity: Mandated by UAE Ministry of Health and Prevention (MOHAP) for all organ transplant procedures; DHA-licensed under facility number 1143.
Test Overview & Methodology
The Government-Approved Transplant Form 5 DNA Test is a mandatory genetic compatibility assessment required by the UAE Ministry of Health and Prevention for all organ transplant procedures. This high-resolution Human Leukocyte Antigen (HLA) typing uses Next-Generation Sequencing (NGS) to ensure precise donor-recipient matching at the allele level, minimizing graft rejection risk and supporting safe transplantation outcomes.
| Aspect | Our Test (NGS HLA Typing) | Closest Alternative (Serology) |
|---|---|---|
| Precision | 99.9% Diagnostic Sensitivity, 4-digit allele-level resolution | Low Resolution, broad antigen groups only |
| Method | NGS with Sanger confirmation & bioinformatics analysis | CDC crossmatch, ELISA serology |
| Speed | 5–7 working days | 2–3 weeks |
Physician Insight & Safety Protocols
“High-resolution HLA typing via NGS provides the immunological precision necessary for safe organ transplantation. The resulting compatibility profile supports the transplant board in making clinically informed decisions, but final clearance always requires complete hematological and infectious disease correlation.” — Lina Osama Zaki Quteineh | Consultant Medical Genetics | DHA Registration ID: 9294403
Medication & Clinical Advisory
Do not discontinue or alter any prescribed immunosuppressive therapy or transplant-related medication without explicit instruction from your treating physician. Sudden changes can compromise transplant outcomes and patient safety.
Safety Exclusion Criteria & Emergency Red Flags
- Uncontrolled active infection (fever, sepsis) must be resolved before sample collection.
- Recent blood transfusion (within 3 months) may affect lymphocyte chimerism, leading to inaccurate results.
- Current high-dose immunosuppressive therapy (e.g., steroids, calcineurin inhibitors) requires physician clearance.
- Seek immediate medical attention if you experience: severe bleeding, large hematoma at puncture site, dizziness, or signs of systemic reaction after blood draw.
Patient FAQ & Clinical Guidance
1. What is the Government-Approved Transplant Form 5 DNA Test?
This test is a mandatory high-resolution HLA typing required by UAE health authorities to determine donor-recipient tissue compatibility before organ transplantation, ensuring graft survival and reducing the risk of rejection.
2. How is the sample collected and what is the turnaround time?
A certified phlebotomist collects a peripheral blood sample via VIP Mobile Phlebotomy at your home or preferred location. Temperature-controlled cold-chain logistics ensure sample integrity. Results are delivered within 5 to 7 working days.
3. Is this test covered by insurance and is it legally valid?
Yes, the test is directly billable to major UAE insurers. It holds full legal validity for transplant workups and is recognized by MOHAP and the Dubai Health Authority (DHA) for all regulated transplantation programs.
UAE Regulatory & Data Privacy Adherence
This service operates in full compliance with Federal Decree-Law No. 45 of 2021 on Personal Data Protection (PDPL) and Federal Law No. 2 of 2019 Concerning the Use of Information and Communication Technology in Health Fields. Clinical testing and patient consent procedures adhere to Federal Decree-Law No. 4 of 2016 on Medical Liability. The facility is certified ISO 9001:2015 (Cert: INT/EGQ/2509DA/3139) and holds a valid DHA facility license.
Clinical & Logistical Metadata
| Test Name | Government-Approved Transplant Form 5 DNA Test (High-Resolution HLA Typing by NGS) |
| Price (AED) | 1000 |
| Turnaround Time | 5–7 working days |
| Sample Type / Matrix | Peripheral whole blood (EDTA tube) |
| Methodology Used | Next-Generation Sequencing (NGS) with Sanger confirmation & bioinformatics analysis |
| ICD-10-CM Code | Z01.818 |
| LOINC Code | 49385-6 |
| DHA Facility License & Laboratory Address | DHA Facility License Number: 1143 | DNA Labs UAE | Premises 105, Floor 1, Building 33, Dubai Healthcare City, Dubai, UAE |
دعم ثنائي اللغة متاح
التحقق من التغطية التأمينية
Check Insurance Coverage Instantly
Stop the guesswork. Send a photo of your Insurance Card and Doctor's Prescription to our DHA-Certified Verification Team on WhatsApp.
توقف عن التخمين. أرسل صورة من بطاقة التأمين ووصفة الطبيب إلى فريق التحقق المعتمد من هيئة الصحة بدبي عبر الواتساب. احصل على تحديث الحالة في دقائق.
Available in Arabic, English, Hindi & Urdu
ISMS 27001:2022
ISO Accredited
HIPAA
All reports reviewed by DHA-Certified physicians