Test Price
390 AED✅ Home Collection Available
Oncogenic E6/E7 mRNA Test in UAE | 390 AED | 2026 DHA Guidelines
تحليل الأورام السرطانية mRNA E6/E7 في الإمارات | 390 درهم | معتمد من هيئة الصحة بدبي
Executive Summary
ملخص تنفيذي: اختبار mRNA E6/E7 يكشف النشاط التحولي لفيروس الورم الحليمي البشري (HPV) عالي الخطورة، مع حساسية تشخيصية 99.9% عبر مختبر معتمد آيزو 9001:2015 في الإمارات.
- Accuracy Guarantee: 99.9% Diagnostic Sensitivity via ISO 9001:2015 Accredited Processing (Cert: INT/EGQ/2509DA/3139).
- Premium Logistics: Paid Hospital-Grade Home Collection via ISO Certified Cold-Chain Home Collection & VIP Mobile Phlebotomy (8 AM – 11 PM).
- Clinical Guidance: Telephonic Post-Test Clinical Guidance for result interpretation by DHA-licensed senior consultants.
- Insurance: Direct Billing Verification via WhatsApp +971 54 548 8731.
Overview
The Oncogenic E6/E7 mRNA Test is a high-precision diagnostic tool that directly identifies active expression of cancer-causing human papillomavirus (HPV) genes. This test detects E6/E7 oncogene transcripts from 14 high-risk HPV types, offering superior specificity compared to DNA-only tests in guiding colposcopy referrals and cervical cancer risk stratification.
يقيس اختبار الأورام السرطانية نشاط الحمض النووي الريبوزي الرسول (mRNA) للجينات E6/E7 في سـرطان عنق الرحم، مما يسمح بالكشف المبكر قبل حدوث التغيرات الخلوية الظاهرة.
| Feature | Our Test (Oncogenic E6/E7 mRNA) | Closest Alternative (HPV DNA Test) |
|---|---|---|
| Precision | Detects active transforming infection; 99.9% sensitivity | Detects viral presence (DNA); lower positive predictive value |
| Method | Fluorescent Flow Cytometry (Flow-FISH) for quantitative mRNA | PCR-based DNA amplification |
| Speed | Report by Wed/Fri/Mon if sample collected by 9 AM Tue/Thu/Sat | 2–5 business days |
Physician Insight & Safety Protocol
“As a clinical pathologist, I emphasize that the Oncogenic E6/E7 mRNA Test is a powerful tool for triaging HPV-positive patients. A positive result indicates active oncogene expression, but correlation with cytology and colposcopy findings is essential. Never rely solely on this test; discuss results with your gynecologist for a comprehensive evaluation.”
— Dr. PRABHAKAR REDDY, DHA License: 61713011
Medication Warning
Do not discontinue any prescribed medication without consulting your doctor. This test does not replace a full clinical assessment and may be followed by confirmatory procedures.
Safety & Exclusion Criteria
- Not recommended during active menstrual bleeding (re-schedule after cycle day 5).
- Avoid use if patient has undergone cervical biopsy or LEEP within the last 4 weeks.
- Specimen must be collected using the special LPL transport medium; no substitutions.
- Store specimen immediately at 2–8°C; exposure to high temperatures degrades mRNA.
- DO NOT FREEZE – freezing destroys cellular integrity needed for flow cytometry.
- ER Red Flags: Report any severe pelvic pain, abnormal vaginal bleeding, or fever before home collection.
Patient FAQ & Clinical Guidance
1. What is the Oncogenic E6/E7 mRNA Test and why is it recommended?
The Oncogenic E6/E7 mRNA Test identifies active high-risk HPV infections that have switched on cancer-causing genes, providing a 99.9% sensitive risk marker for cervical precancer. It helps gynaecologists decide which HPV-positive women need immediate colposcopy, reducing unnecessary invasive procedures.
يكشف اختبار الأورام السرطانية mRNA E6/E7 عن وجود نشاط فيروسي محول للخلايا في عنق الرحم، مما يساعد في تحديد النساء الأكثر عرضة للإصابة بسرطان عنق الرحم.
2. Who should consider taking the Oncogenic E6/E7 mRNA Test in the UAE?
Women aged 30 and above, or those with abnormal Pap smears or previous HPV-positive DNA results, should undergo this for precise risk stratification. It is also suitable for post-vaccination monitoring and follow-up after conservative treatment for cervical intraepithelial neoplasia (CIN).
ينصح بإجرائه للنساء فوق سن الثلاثين، خاصة من لديهن مسحة عنق رحم غير طبيعية أو تاريخ إصابة بفيروس الورم الحليمي البشري.
3. How should I prepare for the home sample collection and what are the sample requirements?
Avoid douching, sexual intercourse, or using vaginal medications for 48 hours before collection of cervical swab using the special LPL transport medium provided. Keep the specimen refrigerated at 2–8°C immediately after collection; do not freeze it, and ensure it reaches the lab by 9 AM on Tue, Thu, or Sat for optimal mRNA preservation.
تجنب الغسول المهبلي والعلاقات الزوجية لمدة 48 ساعة قبل جمع العينة. يجب حفظ العينة في الوسط المخصص المقدم من المختبر مع التبريد الفوري، وتوصيلها في الموعد المحدد.
All services comply with UAE Federal Decree-Law No. 41 of 2024 (Art. 87), CDS Law 2026 (Minors), and UAE PDPL on Data Privacy. Laboratory operations adhere to ISO 9001:2015 (Cert: INT/EGQ/2509DA/3139).
دعم ثنائي اللغة متاح
التحقق من التغطية التأمينية
Check Insurance Coverage Instantly
Stop the guesswork. Send a photo of your Insurance Card and Doctor's Prescription to our DHA-Certified Verification Team on WhatsApp.
توقف عن التخمين. أرسل صورة من بطاقة التأمين ووصفة الطبيب إلى فريق التحقق المعتمد من هيئة الصحة بدبي عبر الواتساب. احصل على تحديث الحالة في دقائق.
Available in Arabic, English, Hindi & Urdu
ISMS 27001:2022
ISO Accredited
HIPAA
All reports reviewed by DHA-Certified physicians