Test Overview & Methodology
The Autoimmune Liver Disease IgG Profile Test uses advanced Immunoblot (Line Blot) technology to detect IgG-class autoantibodies against hepatic antigens such as AMA, LKM-1, LC-1, and SLA/LP. This panel aids in the differential diagnosis of autoimmune hepatitis, primary biliary cholangitis, and overlap syndromes, with a same-day report when the sample reaches the laboratory by 11 AM.
Serum specimens are processed under standardized conditions to ensure reproducible band patterns, enabling confident discrimination between disease subtypes. Correlation with liver enzyme panels and clinical history is recommended for definitive diagnosis.
| Feature | Our IgG Profile (Immunoblot) | Standard ELISA Autoimmune Panel |
|---|---|---|
| Methodology | Line Blot (multiparameter IgG) | Single-parameter ELISA |
| Diagnostic Sensitivity | 98% (comprehensive antigen profile) | ~85% |
| Turnaround Time | Same day (sample by 11 AM) | 3โ5 working days |
| Price | 1500 AED | 1200โ1400 AED (multiple single tests) |
Physician Insight & Safety Protocols
โThe IgG band pattern provides valuable serological evidence, yet it must never be interpreted in isolation. I consistently evaluate these results alongside liver function tests, imaging findings, and the patientโs full clinical picture to build a precise treatment strategy and avoid unnecessary patient anxiety.โ
โ Dr. Ajay Singh | General Practitioner | DHA Registration ID: 36234132
Clinical Advisory
Patients should not stop or alter any prescribed medication without explicit guidance from their treating physician. Immunosuppressive therapy may affect autoantibody levels and test interpretation.
Exclusion Criteria & Emergency Red Flags
- Recent intravenous immunoglobulin (IVIG) therapy โ may cause false-positive band patterns.
- Active systemic infection or sepsis โ postpone non-urgent serological testing.
- Known hypersensitivity to phlebotomy materials or latex.
- Emergency symptoms requiring immediate hospital care: sudden onset jaundice, severe right upper quadrant pain, abdominal distension with ascites, or signs of hepatic encephalopathy.
Patient FAQ & Clinical Guidance
1. What does an elevated IgG autoimmune liver profile indicate?
Elevated IgG autoantibodies detected in the liver profile may point to autoimmune hepatitis, primary biliary cholangitis, or overlap syndromes. Further evaluation by a gastroenterologist or hepatologist is typically required, including liver enzyme testing and possibly imaging or biopsy.
2. Is fasting required before blood collection?
No fasting is necessary for this serum-based test. Patients may eat and drink normally before the blood draw. It is advisable to inform the phlebotomist about any recent IVIG infusions or biologic therapies.
3. How should I interpret the reported IgG band patterns?
Each band on the immunoblot corresponds to a specific liver autoantigen. Interpretation requires correlation with clinical symptoms, liver biochemistry, and imaging studies. Your physician will synthesize all available data to reach a confident diagnosis.
UAE Regulatory & Data Privacy Adherence
Data Protection & Compliance Framework
All patient data processing is conducted in strict accordance with Federal Decree-Law No. 45 of 2021 on Personal Data Protection (PDPL) and Federal Law No. 2 of 2019 Concerning the Use of Information and Communication Technology in Health Fields. Clinical testing safety and patient consent follow Federal Decree-Law No. 4 of 2016 on Medical Liability.
Your clinical information is encrypted at rest and in transit, accessed only by authorized medical personnel directly involved in your care. You retain the right to request access, correction, or deletion of your health records as guaranteed by UAE law.
Clinical & Logistical Metadata
| Test Name | Autoimmune Liver Disease IgG Profile (Immunoblot) |
| Price (AED) | 1500 AED |
| Turnaround Time | Same day (sample arrival by 11 AM) |
| Sample Type / Matrix | Serum (standard peripheral whole blood) |
| Methodology Used | Immunoblot (Line Blot) โ Multiparameter IgG antibody detection |
| ICD-10-CM Code | K75.4 (Autoimmune hepatitis), K74.3 (Primary biliary cholangitis) |
| LOINC Code | 51734-3 (Autoimmune hepatitis panel โ Serum) |
| DHA Facility License & Address | License No: 1143 | Premises 105, Floor 1, Building 33, Dubai Healthcare City, Dubai, UAE | DNA Labs UAE |
ุฏุนู ุซูุงุฆู ุงููุบุฉ ู ุชุงุญ
ุงูุชุญูู ู ู ุงูุชุบุทูุฉ ุงูุชุฃู ูููุฉ
Check Insurance Coverage Instantly
Stop the guesswork. Send a photo of your Insurance Card and Doctor's Prescription to our DHA-Certified Verification Team on WhatsApp.
ุชููู ุนู ุงูุชุฎู ูู. ุฃุฑุณู ุตูุฑุฉ ู ู ุจุทุงูุฉ ุงูุชุฃู ูู ููุตูุฉ ุงูุทุจูุจ ุฅูู ูุฑูู ุงูุชุญูู ุงูู ุนุชู ุฏ ู ู ููุฆุฉ ุงูุตุญุฉ ุจุฏุจู ุนุจุฑ ุงููุงุชุณุงุจ. ุงุญุตู ุนูู ุชุญุฏูุซ ุงูุญุงูุฉ ูู ุฏูุงุฆู.
Available in Arabic, English, Hindi & Urdu
ISMS 27001:2022
ISO Accredited
HIPAA
All reports reviewed by DHA-Certified physicians