Test Price
3,200 AED✅ Home Collection Available
Hypersensitivity Pneumonitis Screen in UAE | 3200 AED | DHA Licensed
Executive Summary & Core Metrics
Diagnostic Accuracy: 99.9% diagnostic specificity through ISO 9001:2015 certified laboratory processing.
Logistics Excellence: VIP Mobile Phlebotomy & Temperature-Controlled Cold-Chain Home Collection available daily from 8 AM to 11 PM.
Clinical Guidance: Post-test telephone consultation for result interpretation.
Insurance Verification: Direct coverage check via WhatsApp +971 54 548 8731.
Test Overview & Methodology
The Hypersensitivity Pneumonitis Screen is a serological panel that detects precipitating IgG antibodies against common organic antigens, aiding in the diagnosis of hypersensitivity pneumonitis (extrinsic allergic alveolitis). This Ouchterlony double immunodiffusion assay measures immune response to avian proteins, fungi, and thermophilic actinomycetes, providing a critical differential tool for interstitial lung disease in the UAE.
| Feature | Our Test (Immunodiffusion) | Alternative (ELISA Panel) |
|---|---|---|
| Precision | 99.9% diagnostic specificity; gold standard for IgG detection | Higher false positives; lower specificity |
| Methodology | Ouchterlony double immunodiffusion – visual precipitin lines | Enzyme-linked immunosorbent assay (ELISA) |
| Turnaround Time | Sample accepted by 7th of month; report in 2–3 weeks | Often faster (3–5 days) |
| Clinical Utility | Confirms specific antigen identification; essential for hypersensitivity pneumonitis management | Screening only; may require confirmation |
Physician Insight & Safety Protocols
"As a clinician, I recognize that unexplained breathlessness and persistent cough can be distressing. This screen is a valuable step in identifying an allergic lung reaction, yet results must always be interpreted alongside clinical history and imaging studies. Do not alter or stop any prescribed medication without consulting your physician, as abrupt changes may worsen your condition."
— Dr. Ajay Singh, General Practitioner | DHA Registration ID: 36234132
Medication Advisory
Do not discontinue any prescribed medication without consulting your doctor. Abrupt cessation may lead to deterioration of your underlying condition.
Safety Exclusion Criteria & Emergency Red Flags
- Exclusion Criteria: Active hemoptysis, acute respiratory distress, severe coagulopathy (INR > 1.5), or inability to provide informed consent.
- Emergency Red Flags: If you experience sudden severe shortness of breath at rest, cyanosis (blue lips/fingers), high fever > 39°C, or fainting, seek emergency care immediately.
Patient FAQ & Clinical Guidance
1. What does the Hypersensitivity Pneumonitis Screen detect?
The Hypersensitivity Pneumonitis Screen detects IgG antibodies to common organic dusts such as avian proteins and fungi, confirming an allergic reaction in the lungs. The immunodiffusion method visualizes specific precipitin bands, indicating sensitization to antigens found in bird droppings, moldy hay, or contaminated humidifiers.
2. How should I prepare for the test?
No special preparation is required. A completed Send Out Consent Form (Form 35) is mandatory before sample collection. Maintain your normal routine; fasting is not necessary. Our home collection team will guide you through the quick venous blood draw.
3. What are the risks of untreated hypersensitivity pneumonitis?
Untreated hypersensitivity pneumonitis can progress to irreversible pulmonary fibrosis, respiratory failure, and chronic disability. Early detection through this screen enables antigen avoidance, corticosteroid therapy, and lung-protective measures to halt disease progression.
UAE Regulatory & Data Privacy Adherence
✅UAE Regulatory Compliance: This service adheres to Federal Decree-Law No. 45 of 2021 on Personal Data Protection (PDPL) and Federal Law No. 2 of 2019 Concerning the Use of Information and Communication Technology in Health Fields. Clinical safety and patient consent follow Federal Decree-Law No. 4 of 2016 on Medical Liability. Our laboratory holds ISO 9001:2015 certification (Cert: INT/EGQ/2509DA/3139) under DHA Facility License 1143.
For Home Collection (8 AM – 11 PM) or insurance verification, contact us via WhatsApp: +971 54 548 8731.
Clinical & Logistical Metadata
| Test Name | Hypersensitivity Pneumonitis Screen |
| Price (AED) | 3,200 AED |
| Turnaround Time | 2–3 weeks (sample accepted by 7th of month) |
| Sample Type / Matrix | Serum (venous blood) – VIP Mobile Phlebotomy & Temperature-Controlled Cold-Chain Home Collection (daily 8 AM – 11 PM) |
| Methodology Used | Ouchterlony Double Immunodiffusion |
| ICD-10-CM Code | J67.9 |
| LOINC Code | 100371-8 |
| DHA Facility License & Laboratory Address | DHA License No: 1143 | Premises 105, Floor 1, Building 33, Dubai Healthcare City, Dubai, UAE | DNA Labs UAE |
دعم ثنائي اللغة متاح
التحقق من التغطية التأمينية
Check Insurance Coverage Instantly
Stop the guesswork. Send a photo of your Insurance Card and Doctor's Prescription to our DHA-Certified Verification Team on WhatsApp.
توقف عن التخمين. أرسل صورة من بطاقة التأمين ووصفة الطبيب إلى فريق التحقق المعتمد من هيئة الصحة بدبي عبر الواتساب. احصل على تحديث الحالة في دقائق.
Available in Arabic, English, Hindi & Urdu
ISMS 27001:2022
ISO Accredited
HIPAA
All reports reviewed by DHA-Certified physicians