Test Price
1,400 AEDโ Home Collection Available
Marburg, Lassa & Ebola Multiplex Detection and Differentiation (RNA Detection) Qualitative Test in UAE | 1400 AED
Executive Summary & Core Metrics
Core Metrics
- Accuracy Guarantee: 99.9% Diagnostic Sensitivity via ISO Accredited Processing.
- Premium Logistics: Hospital extraction only โ sample collection is conducted strictly within an accredited hospital facility; mobile home phlebotomy is disabled for safety.
- Clinical Guidance: Telephonic Post-Test Clinical Guidance in result interpretation.
- Insurance: Direct Billing Verification via WhatsApp +971 54 548 8731.
Test Overview & Methodology
This advanced multiplex RNA detection assay utilises gold-standard Real-Time PCR (qPCR) with confirmatory Whole Genome Sequencing (WGS) to simultaneously identify and differentiate Marburg, Lassa, and Ebola viral RNA in diverse clinical specimens. In the UAE, this test is essential for travellers from endemic regions and supports rapid clinical decision-making with results delivered within 48 hours.
| Feature | Our Test (Multiplex qPCR + WGS) | Standard Single-Pathogen PCR |
|---|---|---|
| Precision | 99.9% sensitivity and specificity | 90โ95% sensitivity |
| Method | Multiplex Real-Time PCR + WGS confirmation | Single-target PCR only |
| Turnaround Time | 48 hours (email) / 36 hours (urgent phone) | 72+ hours |
| Accreditation | ISO 9001:2015 (Cert: INT/EGQ/2509DA/3139) | Variable |
Physician Insight & Safety Protocols
โThis multiplex RNA test is a critical tool for rapid differential diagnosis of viral hemorrhagic fevers. Clinicians must interpret results alongside travel history, clinical presentation, and viral load dynamics. A negative result does not rule out early infection; repeat testing and close clinical correlation are essential for safe management.โ
โ Dr. Ajay Singh, General Practitioner, DHA Registration ID: 36234132
Medication Advisory
Do not discontinue any prescribed medication without consulting your treating physician.
Safety Exclusion Criteria & ER Red Flags
- Exclusion Criteria: This test is not recommended for patients currently on antiviral therapy targeting these viruses without clinical context; it should not be used as a standalone screening tool in asymptomatic individuals.
- ER Red Flags: Seek immediate emergency care if you experience sudden high fever (>39ยฐC), bleeding from gums or nose, hematemesis (vomiting blood), melena (black tarry stools), severe abdominal pain, or confusion.
Patient FAQ & Clinical Guidance
1. What does this test detect?
This multiplex PCR test simultaneously detects and differentiates Marburg, Lassa, and Ebola virus RNA in various specimen types. It provides a definitive molecular diagnosis for viral hemorrhagic fevers, utilising multiple specimen matrices including whole blood, serum, plasma, CSF, oral fluid, swabs, and other bodily fluids to ensure comprehensive pathogen identification.
2. How quickly will I receive my results?
Results are delivered by email within 48 hours, and an urgent phone notification is available within 36 hours. This accelerated turnaround is critical for initiating timely infection control measures and treatment, especially for high-risk travellers returning to the UAE from endemic zones.
3. Is this test covered by UAE health insurance?
We offer direct billing verification with major insurers; WhatsApp policy details to +971545488731 for confirmation. Our concierge team checks your coverage prior to sample collection, ensuring a seamless experience without upfront financial surprises.
UAE Regulatory & Data Privacy Adherence
Data Protection: All personal data is handled in compliance with Federal Decree-Law No. 45 of 2021 on Personal Data Protection (PDPL) and Federal Law No. 2 of 2019 Concerning the Use of Information and Communication Technology in Health Fields. Clinical safety and patient consent follow Federal Decree-Law No. 4 of 2016 on Medical Liability. Sample processing is performed under ISO 9001:2015 certification (Cert: INT/EGQ/2509DA/3139).
Clinical & Logistical Metadata
| Test Name | Marburg, Lassa & Ebola Multiplex Detection and Differentiation (RNA Detection) Qualitative Test |
| Price (AED) | 1,400 AED |
| Turnaround Time | 48 hours (email); 36 hours (urgent phone) |
| Sample Type / Matrix | Whole blood, Serum, Plasma, Cerebrospinal Fluid (CSF), Oral fluid, Swabs. Hospital extraction only โ sample collection is conducted strictly within an accredited hospital facility; mobile home phlebotomy is disabled for safety. |
| Methodology Used | Multiplex Real-Time PCR (qPCR) with confirmatory Whole Genome Sequencing (WGS) |
| ICD-10-CM Code | A98.8 (Other specified viral hemorrhagic fevers) |
| LOINC Code | 94085-4 (Viral hemorrhagic fever virus RNA panel - Specimen by NAA with probe detection) |
| DHA Facility License & Laboratory Address | DHA License No. 1143 | Premises 105, Floor 1, Building 33, Dubai Healthcare City, Dubai, UAE | Corporate Lab: DNA Labs UAE |
ุฏุนู ุซูุงุฆู ุงููุบุฉ ู ุชุงุญ
ุงูุชุญูู ู ู ุงูุชุบุทูุฉ ุงูุชุฃู ูููุฉ
Check Insurance Coverage Instantly
Stop the guesswork. Send a photo of your Insurance Card and Doctor's Prescription to our DHA-Certified Verification Team on WhatsApp.
ุชููู ุนู ุงูุชุฎู ูู. ุฃุฑุณู ุตูุฑุฉ ู ู ุจุทุงูุฉ ุงูุชุฃู ูู ููุตูุฉ ุงูุทุจูุจ ุฅูู ูุฑูู ุงูุชุญูู ุงูู ุนุชู ุฏ ู ู ููุฆุฉ ุงูุตุญุฉ ุจุฏุจู ุนุจุฑ ุงููุงุชุณุงุจ. ุงุญุตู ุนูู ุชุญุฏูุซ ุงูุญุงูุฉ ูู ุฏูุงุฆู.
Available in Arabic, English, Hindi & Urdu
ISMS 27001:2022
ISO Accredited
HIPAA
All reports reviewed by DHA-Certified physicians