Skip to main content

Test Price

550 AED

โœ… Home Collection Available

Factor IX Functional Test in UAE | 550 AED | DNA Labs UAE

Executive Summary & Core Metrics

  • Accuracy Guarantee: 99.9% Diagnostic Sensitivity via ISO Accredited Processing.
  • Premium Logistics: VIP Mobile Phlebotomy & Temperature-Controlled Cold-Chain Home Collection available daily from 8 AM to 11 PM.
  • Clinical Guidance: Telephonic Post-Test Clinical Guidance for result interpretation.
  • Insurance: Direct Billing Verification via WhatsApp +971 54 548 8731.

Test Overview & Methodology

The Factor IX Functional Test quantitatively measures the enzymatic activity of coagulation factor IX in platelet-poor plasma. This assay is essential for diagnosing hemophilia B, determining carrier status, and monitoring factor replacement therapy. Using photo-optical clot detection, the test provides precise, standardized results to guide clinical management.

Feature Our Test (Factor IX Functional) Closest Alternative (PTT-Based Factor IX)
Precision & Quantification Quantitative activity level (%) with high sensitivity Qualitative/semiโ€‘quantitative; often normal in mild deficiency
Methodology Photo-optical Clot Detection (automated, standardized) Activated Partial Thromboplastin Time (aPTT) screening
Turnaround Speed 2-3 Working Days Often longer, dependent on reflexive testing

Physician Insight & Safety Protocols

"The Factor IX functional assay is a critical tool for evaluating hemophilia B and monitoring replacement therapy. Test results must be interpreted in conjunction with clinical history and other coagulation studies. Patients should never alter their medication based solely on a laboratory result without explicit consultation with their treating physician." โ€” Dr. Ajay Singh | General Practitioner | DHA Registration ID: 36234132

Medication Advisory

Do not discontinue prescribed anticoagulants or heparin without explicit consent from your treating physician. Discontinuation must be medically supervised to avoid thromboembolic complications.

Exclusion Criteria & Emergency Red Flags

  • Exclusion Criteria: Not indicated in acute uncontrolled bleeding or thrombosis; delay testing until clinically stable.
  • Red Flags: Sudden severe joint or muscle bleeding, hematuria, altered consciousness, or uncontrolled external bleeding. Seek emergency care immediately.

Patient FAQ & Clinical Guidance

1. What is the Factor IX Functional Test?

This test quantifies the enzymatic activity of coagulation factor IX in plasma. It is primarily used to diagnose hemophilia B (Christmas disease), identify carrier status, and monitor the efficacy of factor replacement therapy. Results are reported as a percentage of normal activity, guiding clinical management.

2. How should I prepare for this test?

Overnight fasting is preferred to minimize lipid interference. The blood sample must be collected in a citrate tube and processed rapidly to obtain platelet-poor plasma. If transport is delayed beyond 4 hours, the plasma should be frozen. Our VIP mobile phlebotomy team is trained to handle such specialized requirements.

3. How do I interpret my Factor IX activity results?

Factor IX activity reference range is typically 50โ€“150%. Severe hemophilia B is classified by activity less than 1%, moderate deficiency by 1โ€“5%, and mild deficiency by 5โ€“50%. Results must always be correlated with bleeding history, family studies, and other laboratory findings. A specialist consultation is recommended for abnormal results.

UAE Regulatory & Data Privacy Adherence

Compliance Framework: This service adheres to Federal Decree-Law No. 45 of 2021 on Personal Data Protection (PDPL) and Federal Law No. 2 of 2019 Concerning the Use of Information and Communication Technology in Health Fields. Clinical safety, patient consent, and medical liability are governed by Federal Decree-Law No. 4 of 2016 on Medical Liability. DNA Labs UAE is fully licensed by the Dubai Health Authority (DHA) under license number 1143.

Clinical & Logistical Metadata

Test Name Factor IX Functional Test
Price (AED) 550
Turnaround Time 2-3 Working Days
Sample Type / Matrix Citrate Plasma (Whole Blood)
Methodology Used Photo-optical Clot Detection
ICD-10-CM Code D66, Z86.7
LOINC Code 34665-5
DHA Facility License & Address License No: 1143 | Premises 105, Floor 1, Building 33, Dubai Healthcare City, Dubai, UAE

ุฏุนู… ุซู†ุงุฆูŠ ุงู„ู„ุบุฉ ู…ุชุงุญ

ุงู„ุชุญู‚ู‚ ู…ู† ุงู„ุชุบุทูŠุฉ ุงู„ุชุฃู…ูŠู†ูŠุฉ

Check Insurance Coverage Instantly

Stop the guesswork. Send a photo of your Insurance Card and Doctor's Prescription to our DHA-Certified Verification Team on WhatsApp.

ุชูˆู‚ู ุนู† ุงู„ุชุฎู…ูŠู†. ุฃุฑุณู„ ุตูˆุฑุฉ ู…ู† ุจุทุงู‚ุฉ ุงู„ุชุฃู…ูŠู† ูˆูˆุตูุฉ ุงู„ุทุจูŠุจ ุฅู„ู‰ ูุฑูŠู‚ ุงู„ุชุญู‚ู‚ ุงู„ู…ุนุชู…ุฏ ู…ู† ู‡ูŠุฆุฉ ุงู„ุตุญุฉ ุจุฏุจูŠ ุนุจุฑ ุงู„ูˆุงุชุณุงุจ. ุงุญุตู„ ุนู„ู‰ ุชุญุฏูŠุซ ุงู„ุญุงู„ุฉ ููŠ ุฏู‚ุงุฆู‚.

โœ… DHA Certified โœ… ISO 15189 โœ… HIPAA Compliant

Available in Arabic, English, Hindi & Urdu

๐Ÿ…

ISMS 27001:2022

๐Ÿ“‹

ISO Accredited

๐Ÿ”’

HIPAA

All reports reviewed by DHA-Certified physicians