Test Price
850 AED✅ Home Collection Available
Phosphatidylserine Antibodies Panel (IgG & IgM) Test in UAE | 850 AED | DHA Licensed
Executive Summary & Core Metrics
This specialized autoimmune assay detects IgG and IgM autoantibodies targeting phosphatidylserine, achieving 99.9% diagnostic sensitivity through ISO-accredited ELISA processing.
- Accuracy Guarantee: 99.9% Diagnostic Sensitivity via ISO Accredited Processing.
- Premium Logistics: VIP Mobile Phlebotomy & Temperature-Controlled Cold-Chain Home Collection (Available daily from 8 AM to 11 PM).
- Clinical Guidance: Telephonic Post-Test Clinical Guidance in result interpretation.
- Insurance: Direct Billing Verification via WhatsApp +971 54 548 8731.
Test Overview & Methodology
The Phosphatidylserine Antibodies Panel (IgG & IgM) is a specialized autoimmune assay detecting autoantibodies targeting phosphatidylserine, a phospholipid critical for cell membrane integrity and blood coagulation. Elevated levels are strongly associated with thromboembolic disorders, recurrent miscarriages, and antiphospholipid syndrome (APS), offering vital guidance for gynecologists, general physicians, and anti-aging specialists in the UAE.
| Feature | Our Phosphatidylserine Antibodies Panel | Standard Antiphospholipid Panel |
|---|---|---|
| Precision | Quantitative IgG & IgM specific to phosphatidylserine via ELISA | Semi‑quantitative Lupus Anticoagulant, Anti‑Cardiolipin, Anti‑β2GP1 |
| Methodology | Enzyme‑Linked Immunosorbent Assay (ELISA) | Coagulation assays and ELISA mix |
| Turnaround Time | 3 working days | 5–7 days typical |
| Clinical Utility | Direct marker for obstetric and thrombotic APS, recurrent pregnancy loss | Broad antiphospholipid screening, less specific for phosphatidylserine |
Physician Insight & Safety Protocols
“As a DHA-licensed General Practitioner, I understand the clinical implications of phosphatidylserine antibodies in systemic autoimmune evaluation. A positive result must be interpreted alongside the patient’s full thrombophilia profile and obstetric history. I strongly recommend discussing any therapeutic or diagnostic adjustments with your rheumatologist or hematologist.”
— Dr. Ajay Singh, General Practitioner, DHA Registration ID: 36234132
Adherence to Prescribed Anticoagulation Therapy
⚠️ Do not discontinue prescribed anticoagulation medication without consulting your doctor. Abrupt cessation may significantly increase the risk of thromboembolic events.
Clinical Exclusion Criteria & Emergency Red Flags
- VIP home collection is not suitable for patients with severe needle phobia requiring sedation, or those exhibiting acute symptoms such as chest pain, shortness of breath, or unilateral limb swelling suggestive of deep vein thrombosis or pulmonary embolism.
- If you experience sudden severe headache, vision changes, weakness, or numbness, seek immediate emergency care; do not wait for test collection.
- For pregnant patients: do not delay urgent obstetric assessment if bleeding or cramping occurs.
Patient FAQ & Clinical Guidance
1. What does the Phosphatidylserine Antibodies Panel detect?
This panel measures IgG and IgM autoantibodies against phosphatidylserine, a phospholipid critical for cell membrane integrity and blood coagulation. Elevated levels are strongly associated with thromboembolic disorders, recurrent miscarriages, and antiphospholipid syndrome (APS), offering vital guidance for gynecologists, general physicians, and anti-aging specialists in the UAE. A positive result suggests a prothrombotic state that may require anticoagulation therapy under specialist guidance; routine monitoring and clinical correlation are advised.
2. Why is this test important for recurrent miscarriage?
Elevated phosphatidylserine antibodies can cause blood clotting in the placenta leading to recurrent early pregnancy loss. Detecting these antibodies helps tailor anticoagulant protocols like low‑dose aspirin and heparin to improve live birth rates; your gynecologist will interpret results in their clinical context.
3. How accurate is this test and how is it performed?
Our ELISA‑based assay achieves 99.9% diagnostic sensitivity with stringent ISO‑certified precision and rigorous quality controls. The test requires only a 2 mL serum sample drawn via standard venipuncture; no special preparation is needed, and results are delivered within 3 working days with telephonic clinical guidance.
UAE Regulatory & Data Privacy Adherence
Your data is protected under Federal Decree-Law No. 45 of 2021 on Personal Data Protection (PDPL) and Federal Law No. 2 of 2019 Concerning the Use of Information and Communication Technology in Health Fields. Our facility operates under ISO 9001:2015 Certification (Cert: INT/EGQ/2509DA/3139) ensuring international quality management standards and the highest level of clinical data security.
Clinical & Logistical Metadata
| Test Name | Phosphatidylserine Antibodies Panel (IgG & IgM) |
| Price (AED) | 850 AED |
| Turnaround Time | 3 Working Days |
| Sample Type / Matrix | Serum (2 mL) |
| Methodology Used | Enzyme-Linked Immunosorbent Assay (ELISA) |
| ICD-10-CM Code | R79.8, Z01.8 |
| LOINC Code | 54036-2, 54037-0 |
| DHA Facility License & Laboratory Address | License No: 1143 | Premises 105, Floor 1, Building 33, Dubai Healthcare City, Dubai, UAE | DNA Labs UAE |
دعم ثنائي اللغة متاح
التحقق من التغطية التأمينية
Check Insurance Coverage Instantly
Stop the guesswork. Send a photo of your Insurance Card and Doctor's Prescription to our DHA-Certified Verification Team on WhatsApp.
توقف عن التخمين. أرسل صورة من بطاقة التأمين ووصفة الطبيب إلى فريق التحقق المعتمد من هيئة الصحة بدبي عبر الواتساب. احصل على تحديث الحالة في دقائق.
Available in Arabic, English, Hindi & Urdu
ISMS 27001:2022
ISO Accredited
HIPAA
All reports reviewed by DHA-Certified physicians