Sale!

TB LAMP Loop Mediated Isothermal Amplification Qualitative DNA PCR Mycobacterium Tuberculosis Complex Test

Original price was: 1,300 د.إ.Current price is: 1,000 د.إ.

-23%

The “TB LAMP (Loop Mediated Isothermal Amplification) Qualitative DNA PCR Mycobacterium Tuberculosis Complex Test” is a cutting-edge diagnostic procedure designed to rapidly and accurately detect the presence of Mycobacterium tuberculosis complex, the bacteria responsible for tuberculosis (TB), in a patient’s sample. Unlike traditional PCR tests that require cycles of temperature changes, the LAMP method performs DNA amplification at a constant temperature, making the process faster and less resource-intensive. This test is particularly useful in settings where quick and reliable results are crucial for the timely treatment of TB.

Conducted at DNA Labs UAE, a leading facility in genetic and molecular diagnostics, the test offers a high degree of sensitivity and specificity. The cost of the test is set at 1000 AED, reflecting the advanced technology and expertise involved in providing accurate and reliable results. This test is an essential tool in the fight against tuberculosis, facilitating early detection and the initiation of appropriate treatment strategies to combat this serious infectious disease.

Home  Sample collection service available

  • 100% accuaret Test Results
  • Ranked as Most trusted Genetic DNA Lab
  • This test is not intended for medical diagnosis or treatment
Guaranteed Safe Checkout

TB LAMP LOOP MEDIATED ISOTHERMA AMPLIFICATION QUALITATIVE DNA PCR MYCOBACTERIUM TUBERCULOSIS COMPLEX Test

Test Components

  • Price: 1000.0 AED

Sample Condition

1-2 mL preferably first morning Sputum / Induced Sputum / Bronchial Lavage / Aspirate / Brushings / Endotracheal secretions / Gastric lavage OR 2-5 mL Body Fluids like Pleural Fluid, Ascitic fluid, Peritoneal fluid, Pericardial fluid, Synovial fluid, Semen, CSF & Ocular fluid in a sterile screw capped container OR 2-5 gm Fresh Tissue biopsy / Lymph node / Endometrium in normal saline OR 5-10 mL first morning Urine in a sterile screw capped container. Ship refrigerated. DO NOT FREEZE. Whole blood sample is not acceptable.

Report Delivery

Sample Daily by 11 am; Report Same day

Method

LAMP

Test Type

Tuberculosis

Doctor

Physician, Chest Physician

Test Department

Pre Test Information

No special preparation required

Test Details

The TB LAMP (Loop Mediated Isothermal Amplification) Qualitative DNA PCR Mycobacterium tuberculosis complex test is a diagnostic test used to detect the presence of Mycobacterium tuberculosis complex DNA in a patient’s sample. The test is based on the principle of isothermal amplification, which allows for the rapid amplification of target DNA without the need for complex and time-consuming thermal cycling. It specifically targets a conserved region of the M. tuberculosis complex genome, ensuring accurate detection of the bacteria. The test is qualitative, meaning it can determine the presence or absence of M. tuberculosis complex DNA in a sample, but it does not provide quantitative information such as the bacterial load. It is primarily used as an initial screening tool for tuberculosis (TB) diagnosis, especially in resource-limited settings where access to more advanced molecular techniques like PCR (Polymerase Chain Reaction) may be limited. The TB LAMP test is highly sensitive and specific, with a turnaround time of around 1-2 hours. It is performed on various clinical samples such as sputum, bronchoalveolar lavage fluid, cerebrospinal fluid, and tissue biopsies. The test can aid in the early detection of TB, allowing for prompt initiation of treatment and reducing the risk of transmission to others.

Test Name TB LAMP LOOP MEDIATED ISOTHERMA AMPLIFICATION QUALITATIVE DNA PCR MYCOBACTERIUM TUBERCULOSIS COMPLEX Test
Components
Price 1000.0 AED
Sample Condition 1-2 mLpreferably first morning Sputum \/ Induced Sputum \/ Bronchial Lavage \/ Aspirate\/ Brushings \/ Endotracheal secretions \/ Gastric lavage OR2-5 mL Body Fluids like Pleural Fluid, Ascitic fluid, Peritoneal fluid, Pericardial fluid, Synovial fluid, Semen, CSF & Ocular fluid in a sterile screw capped container OR 2-5 gm Fresh Tissue biopsy \/ Lymph node \/ Endometrium in normal saline OR 5-10 mL first morningUrine in asterile screw capped container. Ship refrigerated. DO NOT FREEZE. Whole blood sample is not acceptable.
Report Delivery Sample Daily by 11 am; Report Same day
Method LAMP
Test type Tuberculosis
Doctor Physician, Chest Physician
Test Department:
Pre Test Information No special preparation required
Test Details

The TB LAMP (Loop Mediated Isothermal Amplification) Qualitative DNA PCR Mycobacterium tuberculosis complex test is a diagnostic test used to detect the presence of Mycobacterium tuberculosis complex DNA in a patient’s sample.

The test is based on the principle of isothermal amplification, which allows for the rapid amplification of target DNA without the need for complex and time-consuming thermal cycling. It specifically targets a conserved region of the M. tuberculosis complex genome, ensuring accurate detection of the bacteria.

The test is qualitative, meaning it can determine the presence or absence of M. tuberculosis complex DNA in a sample, but it does not provide quantitative information such as the bacterial load. It is primarily used as an initial screening tool for tuberculosis (TB) diagnosis, especially in resource-limited settings where access to more advanced molecular techniques like PCR (Polymerase Chain Reaction) may be limited.

The TB LAMP test is highly sensitive and specific, with a turnaround time of around 1-2 hours. It is performed on various clinical samples such as sputum, bronchoalveolar lavage fluid, cerebrospinal fluid, and tissue biopsies. The test can aid in the early detection of TB, allowing for prompt initiation of treatment and reducing the risk of transmission to others.