Sale!

Immunophenotyping by Flow Cytometry CD8 Test Cost

Original price was: 620 د.إ.Current price is: 560 د.إ.

-10%

Immunophenotyping by Flow Cytometry CD8 Test is a sophisticated diagnostic procedure employed to analyze the presence and proportion of CD8+ T cells in the blood. These cells are a subset of T lymphocytes that play a crucial role in the immune system, particularly in fighting viral infections and tumors. The test involves using flow cytometry technology, which enables the rapid analysis of thousands of cells in a sample by passing them through a laser beam and detecting different markers, such as the CD8 protein, on the cell surface.

The CD8 Test is particularly useful in monitoring immune system health, diagnosing diseases, and guiding treatment decisions in conditions like HIV/AIDS, where CD8+ T cell levels are a critical marker of immune function. Additionally, it can provide valuable insights into the effectiveness of cancer immunotherapy treatments, as changes in CD8+ T cell levels can indicate how well the body is responding to therapy.

At DNA Labs UAE, this test is offered at a cost of 560 AED. The facility ensures accurate and reliable results by employing state-of-the-art flow cytometry equipment and adhering to stringent quality control measures. Patients opting for the test at DNA Labs UAE can expect professional service, with results that provide crucial insights into their immune system’s status and functioning.

Home  Sample collection service available

  • 100% accuaret Test Results
  • Ranked as Most trusted Genetic DNA Lab
  • This test is not intended for medical diagnosis or treatment
Guaranteed Safe Checkout

IMMUNOPHENOTYPING BY FLOW CYTOMETRY CD8 Test

At DNA Labs UAE, we offer the IMMUNOPHENOTYPING BY FLOW CYTOMETRY CD8 Test. This test is used to determine the presence and quantity of CD8-positive T cells in a sample.

Test Details

The CD8 test is a flow cytometry-based immunophenotyping assay that plays a crucial role in the immune response against viral infections and cancer. During the test, a blood or tissue sample is collected and processed to isolate the immune cells. These cells are then stained with fluorescently labeled antibodies that specifically bind to the CD8 marker. Flow cytometry is used to analyze the stained cells and measure the fluorescence intensity, allowing for the identification and quantification of CD8-positive T cells.

The CD8 test is commonly used in research and clinical settings to assess the immune response, monitor disease progression, and evaluate the effectiveness of immunotherapies. It provides valuable information about the quantity and functionality of CD8-positive T cells, which can help in diagnosing and managing various immune-related disorders.

Test Components and Price

The IMMUNOPHENOTYPING BY FLOW CYTOMETRY CD8 Test costs 560.0 AED. The sample condition required for the test includes 3 mL (2 mL min.) whole blood in 1 Lavender Top (EDTA) tube and 3 mL (2 mL min.) whole blood in 1 Green Top (Sodium Heparin) tube OR 2 mL (1 mL min.) Bone marrow in 1 Green Top (Sodium heparin) tube. The samples should be shipped immediately at 18-22°C and should not be refrigerated or frozen. It is important to specify the time, date, and clinical details on the test request form.

Report Delivery

The sample should be delivered daily by 9 am, and the report will be available on the same day.

Method

The IMMUNOPHENOTYPING BY FLOW CYTOMETRY CD8 Test is performed using flow cytometry.

Test Type

The test is used for the diagnosis of AIDS and immunodeficiency states.

Doctor

The test is conducted under the supervision of a Hematologist.

Test Department

The IMMUNOPHENOTYPING BY FLOW CYTOMETRY CD8 Test is performed in the FLOW CYTOMETRY department.

Pre Test Information

It is important to provide a brief clinical history before conducting the test.

Test Name IMMUNOPHENOTYPING BY FLOW CYTOMETRY CD8 Test
Components
Price 560.0 AED
Sample Condition 3 mL (2 mL min.) whole blood in 1 Lavender Top (EDTA) tubeAND 3 mL (2 mL min.) whole blood in 1 Green Top (Sodium Heparin) tube OR 2 mL (1 mL min.) Bone marrow in 1 Green Top (Sodium heparin) tube. Ship immediately at 18\u0192??22?\u00f8C. DO NOT REFRIGERATE OR FREEZE. Specify time, date and clinical details on test request form.
Report Delivery Sample Daily by 9 am; Report Same day
Method Flow Cytometry
Test type AIDS, Immunodeficiency states
Doctor Hematologist
Test Department: FLOW CYTOMETRY
Pre Test Information Give brief clinical history.
Test Details

The CD8 test is a flow cytometry-based immunophenotyping assay that is used to determine the presence and quantity of CD8-positive T cells in a sample. CD8 is a cell surface marker expressed on cytotoxic T cells, which play a crucial role in the immune response against viral infections and cancer.

During the CD8 test, a blood or tissue sample is collected and processed to isolate the immune cells. These cells are then stained with fluorescently labeled antibodies that specifically bind to the CD8 marker. Flow cytometry is then used to analyze the stained cells and measure the fluorescence intensity, allowing for the identification and quantification of CD8-positive T cells.

The CD8 test is commonly used in research and clinical settings to assess the immune response, monitor disease progression, and evaluate the effectiveness of immunotherapies. It can provide valuable information about the quantity and functionality of CD8-positive T cells, which can help in diagnosing and managing various immune-related disorders.