Sale!

Immunophenotyping by Flow Cytometry CD16 and 56 Test Cost

Original price was: 1,010 د.إ.Current price is: 910 د.إ.

-10%

Immunophenotyping by Flow Cytometry CD16 and 56 Test is a specialized diagnostic procedure performed at DNA Labs UAE. Priced at 910 AED, this test is designed to analyze and quantify the presence of specific cell surface markers, CD16 and CD56, on immune cells. CD16 and CD56 are critical markers for Natural Killer (NK) cells, a type of lymphocyte that plays a pivotal role in the body’s innate immune response. By utilizing flow cytometry, a technique that allows for the detailed analysis of thousands of cells in a short period, this test provides essential information on the distribution and frequency of NK cells within a sample. This can be crucial for diagnosing and monitoring various conditions, including immune deficiencies, autoimmune disorders, and certain types of cancer. DNA Labs UAE employs state-of-the-art technology and expertise to ensure accurate and reliable results, making the Immunophenotyping by Flow Cytometry CD16 and 56 Test a valuable tool in clinical diagnostics and patient care.

Home  Sample collection service available

  • 100% accuaret Test Results
  • Ranked as Most trusted Genetic DNA Lab
  • This test is not intended for medical diagnosis or treatment
Guaranteed Safe Checkout

IMMUNOPHENOTYPING BY FLOW CYTOMETRY CD16 and 56 Test

Test Name: IMMUNOPHENOTYPING BY FLOW CYTOMETRY CD16 and 56 Test

Components: CD16 and 56 Test

Price: 910.0 AED

Sample Condition: 3 mL (2 mL min.) whole blood in 1 Lavender Top (EDTA) tube and 3 mL (2 mL min.) whole blood in 1 Green Top (Sodium Heparin) tube OR 2 mL (1 mL min.) Bone marrow in 1 Green Top (Sodium heparin) tube. Ship immediately at 18-22°C. DO NOT REFRIGERATE OR FREEZE. Specify time, date, and clinical details on the test request form.

Report Delivery: Sample Daily by 9 am; Report Same day

Method: Flow Cytometry

Test Type: Abortions, Cancer

Doctor: Gynecologist, Oncologist, Hematologist

Test Department: FLOW CYTOMETRY

Pre Test Information: Give brief clinical history.

Test Details:

The CD16 + 56 test, also known as the natural killer (NK) cell immunophenotyping test, is performed using flow cytometry to identify and quantify NK cells in a sample. Flow cytometry is a technique that uses fluorescently labeled antibodies to detect specific cell surface markers.

In the case of the CD16 + 56 test, two antibodies are used: CD16 (also known as FcRIII) and CD56. CD16 is a receptor found on the surface of NK cells, while CD56 is a glycoprotein expressed on the surface of NK cells and some T cells.

By labeling the sample with fluorescently labeled antibodies against CD16 and CD56, flow cytometry can identify and quantify NK cells based on their expression of these markers. The fluorescence emitted by the labeled antibodies is detected by a flow cytometer, and the data is analyzed to determine the percentage and absolute number of NK cells in the sample.

The CD16 + 56 test is commonly used in research and clinical settings to study the function and levels of NK cells. NK cells are an important component of the innate immune system and play a critical role in immune surveillance and defense against viral infections and tumor cells.

Abnormalities in NK cell numbers or function can be associated with various diseases, including cancer, autoimmune disorders, and viral infections.

Overall, the CD16 + 56 test by flow cytometry is a valuable tool for immunophenotyping NK cells and studying their role in immune responses and diseases.

Test Name IMMUNOPHENOTYPING BY FLOW CYTOMETRY CD16 and 56 Test
Components
Price 910.0 AED
Sample Condition 3 mL (2 mL min.) whole blood in 1 Lavender Top (EDTA) tubeAND 3 mL (2 mL min.) whole blood in 1 Green Top (Sodium Heparin) tube OR 2 mL (1 mL min.) Bone marrow in 1 Green Top (Sodium heparin) tube.Ship immediately at 18\u0192??22?\u00f8C. DO NOT REFRIGERATE OR FREEZE. Specify time, date and clinical details on test request form.
Report Delivery Sample Daily by 9 am; Report Same day
Method Flow Cytometry
Test type Abortions, Cancer
Doctor Gynecologist, Oncologist, Hematologist
Test Department: FLOW CYTOMETRY
Pre Test Information Give brief clinical history.
Test Details

The CD16 + 56 test, also known as the natural killer (NK) cell immunophenotyping test, is performed using flow cytometry to identify and quantify NK cells in a sample.

Flow cytometry is a technique that uses fluorescently labeled antibodies to detect specific cell surface markers. In the case of the CD16 + 56 test, two antibodies are used: CD16 (also known as FcRIII) and CD56. CD16 is a receptor found on the surface of NK cells, while CD56 is a glycoprotein expressed on the surface of NK cells and some T cells.

By labeling the sample with fluorescently labeled antibodies against CD16 and CD56, flow cytometry can identify and quantify NK cells based on their expression of these markers. The fluorescence emitted by the labeled antibodies is detected by a flow cytometer, and the data is analyzed to determine the percentage and absolute number of NK cells in the sample.

The CD16 + 56 test is commonly used in research and clinical settings to study the function and levels of NK cells. NK cells are an important component of the innate immune system and play a critical role in immune surveillance and defense against viral infections and tumor cells. Abnormalities in NK cell numbers or function can be associated with various diseases, including cancer, autoimmune disorders, and viral infections.

Overall, the CD16 + 56 test by flow cytometry is a valuable tool for immunophenotyping NK cells and studying their role in immune responses and diseases.