Human Immuno Virus 1 RNA QUANTITATIVE REAL TIME PCR WITH CD3 CD4 IMMUNE DEFICIENCY PANEL 4 MARKERS Test
Test Cost: AED 1450.0
Test Components:
- PCR: 3 mL (2 mL min.) plasma from 2 Lavender Top (EDTA) tubes. Separate plasma aseptically within 2 hours of collection. Ship refrigerated or frozen. 12 hours fasting is recommended.
- FLOW: 4 mL (3 mL min.) whole blood from 1 Lavender Top (EDTA) AND 1 Green top (Sodium Heparin) tube each. Ship at 18-22°C. DO NOT REFRIGERATE OR FREEZE. Specify time, date and clinical details on Test Request form.
Report Delivery: Sample – Wed / Sat by 11 am; Report – Fri / Tue
Method: Real Time RT-PCR, Flow Cytometry
Test Type: AIDS
Doctor: Physician
Test Department:
Pre Test Information: 12 hours fasting is recommended.
Test Details:
The Human Immuno Virus 1 RNA Quantitative Real Time PCR with CD3/CD4 (Immune Deficiency Panel 4) Markers Test is a diagnostic test used to measure the amount of Human Immunodeficiency Virus 1 (HIV-1) RNA in a patient’s blood sample. It also includes the analysis of CD3 and CD4 markers, which are used to assess the patient’s immune system function.
The test is performed using a real-time polymerase chain reaction (PCR) technique, which amplifies and detects the HIV-1 RNA present in the sample. The test provides a quantitative measurement of the viral load, which is the amount of HIV-1 RNA in the patient’s blood. This measurement is important for monitoring the progression of HIV infection and evaluating the effectiveness of antiretroviral therapy.
In addition to measuring the viral load, the test also analyzes the CD3 and CD4 markers. CD3 is a protein found on the surface of T cells, which are a type of white blood cell involved in immune response. CD4 is another protein found on the surface of T helper cells, a specific subset of T cells. CD4 cells play a crucial role in coordinating the immune response to infections.
By analyzing the CD3 and CD4 markers, the test provides information about the patient’s immune system function and the impact of HIV infection on the immune system. A decrease in CD4 cell count is often observed in HIV-infected individuals, indicating a weakened immune system.
Overall, the Human Immuno Virus 1 RNA Quantitative Real Time PCR with CD3/CD4 (Immune Deficiency Panel 4) Markers Test is a comprehensive diagnostic tool for monitoring HIV infection, assessing viral load, and evaluating immune system function. It plays a crucial role in the management and treatment of HIV-infected individuals.
Test Name | Human Immuno Virus 1 RNA QUANTITATIVE REAL TIME PCR WITH CD3 CD4 IMMUNE DEFICIENCY PANEL 4 MARKERS Test |
---|---|
Components | |
Price | 1450.0 AED |
Sample Condition | PCR: 3 mL (2 mL min.) plasma from 2 Lavender Top (EDTA) tubes. Separate plasma aseptically within 2 hours of collection. Ship refrigerated or frozen. 12 hours fasting is recommended.\nFLOW: 4 mL (3 mL min.) whole blood from 1 Lavender Top (EDTA) AND 1 Green top (Sodium Heparin) tube each. Ship at 18-22?\u00f8C. DO NOT REFRIGERATE OR FREEZE. Specify time, date and clinical details on Test Request form. |
Report Delivery | SampleWed / Sat by 11 am; ReportFri / Tue |
Method | Real Time RT-PCR, Flow Cytometry |
Test type | AIDS |
Doctor | Physician |
Test Department: | |
Pre Test Information | 12 hours fasting is recommended. |
Test Details |
The Human Immuno Virus 1 RNA Quantitative Real Time PCR with CD3/CD4 (Immune Deficiency Panel 4) Markers Test is a diagnostic test used to measure the amount of Human Immunodeficiency Virus 1 (HIV-1) RNA in a patient’s blood sample. It also includes the analysis of CD3 and CD4 markers, which are used to assess the patient’s immune system function. The test is performed using a real-time polymerase chain reaction (PCR) technique, which amplifies and detects the HIV-1 RNA present in the sample. The test provides a quantitative measurement of the viral load, which is the amount of HIV-1 RNA in the patient’s blood. This measurement is important for monitoring the progression of HIV infection and evaluating the effectiveness of antiretroviral therapy. In addition to measuring the viral load, the test also analyzes the CD3 and CD4 markers. CD3 is a protein found on the surface of T cells, which are a type of white blood cell involved in immune response. CD4 is another protein found on the surface of T helper cells, a specific subset of T cells. CD4 cells play a crucial role in coordinating the immune response to infections. By analyzing the CD3 and CD4 markers, the test provides information about the patient’s immune system function and the impact of HIV infection on the immune system. A decrease in CD4 cell count is often observed in HIV-infected individuals, indicating a weakened immune system. Overall, the Human Immuno Virus 1 RNA Quantitative Real Time PCR with CD3/CD4 (Immune Deficiency Panel 4) Markers Test is a comprehensive diagnostic tool for monitoring HIV infection, assessing viral load, and evaluating immune system function. It plays a crucial role in the management and treatment of HIV-infected individuals. |